Gold Member Since 2014
Audited Supplier
Xi'an Tosilon Automation Co., Ltd.

Differential Pressure Transmitter, Air Pressure Transmitter, Pressure Transmitter manufacturer / supplier in China, offering Intelligent Air (Differential) Pressure Transmitter with Remote Diaphragm Seals (ATEX), Multi Phase Coriolis Mass Flow Meter for Water, Oil, Gas, Coriolis Mass Multiphase Liquid Flow Meter for Diesel Fuel Oil and so on.

(/ )

Supplier Homepage Product Static Pressure Monocrystalline Silicon Intelligent Air (Differential) Pressure Transmitter with Remote Diaphragm Seals (ATEX)

Intelligent Air (Differential) Pressure Transmitter with Remote Diaphragm Seals (ATEX)

FOB Price: US $500-3,000 / Piece
Min. Order: 2 Pieces
Min. Order FOB Price
2 Pieces US $500-3,000/ Piece
Get Latest Price
Production Capacity: 800 Set/Month
Transport Package: International Carton Case Packing
Payment Terms: L/C, T/T, Western Union

Request a custom order and have something just for you!

Send Customized Request
Basic Info
  • Model NO.: RP1001
  • Structure Type: Monocrystalline Silicon
  • Accuracy Grade: 0.075%F.S
  • IP Rating: IP67
  • Customized: Customized
  • Vibration Resistance: 2g up to 500Hz
  • Fill Fluid: Silicone Oil, (Super) High Temp. Silicone Oil
  • Max. Voltage Limited: 42V DC
  • Housing Gasket: Perbunan (NBR)
  • Nuts & Bolts: 304 Ss
  • Specification: As required
  • Type: Differential Pressure Transmitter
  • Measuring Medium: Steam
  • Pressure range: 0 – 2kpa~250kpa
  • Certification: Atex
  • Temperature Limits: -30~400 Deg. C
  • Output: 2-Wire, 4-20mA Via Hart
  • Power Supply: 24V DC
  • Amplifier Housing: Aluminum with Epoxy Resin Coat
  • Electrical Connection: M20X1.5
  • Trademark: Tosilon
  • Origin: Xi′an
Product Description
Tosilon Intelligent Differential Pressure Transmitter with Remote Diaphragm Seals for Liquids (ATEX Approved)
Design and Manufacturing according to ATEX Standard

General Description
The Remote Seal Differential Pressure Transmitter RP1001 is suitable to measure liquid, gas, or steam flow as well as liquid level, density and pressure. RP1001 outputs a 4-20mA DC signal corresponding to the measured differential pressure. Its highly accurate and stable sensor can also measure the static pressure
which can be shown on the integral indicator or remotely monitored via HART communications. Other key features include quick response, remote set-up using communications, self-diagnostics and optional status output for pressure high/low alarm. The range limit is 0-1kPa~2MPa, the flange's working pressure are 1.6/4MPa, 6.4MPa, 10MPa, 150psi, 300psi or 600psi.


Intelligent Air (Differential) Pressure Transmitter with Remote Diaphragm Seals (ATEX)
Span & Range Limits
Span
Code
Measuring RangeSWP (Max.)
Min.Max.
B1kPa6 kPaThe flange's
working pressure
C4 kPa40 kPa
D25 kPa250 kPa
E200 kPa2MPa
 
FlangeNominal
Diameter
The Min.
Measuring Range
1 flange2 flange
Bulge SealingDN 50 / 2"16 kPa16 kPa
DN 80/ 3"6 kPa1 kPa
DN100 / 4"6 kPa1 kPa
Flat SealingDN 50/ 2"10 kPa10 kPa
DN 80 / 3"6 kPa1 kPa
DN 100 / 4"6 kPa1 kPa

Fill Fluid, temperature limits and the working pressure range
Fill FluidSilicone
Oil (S)
High Temp.
Silicone Oil
(H)
Super High
Temp.
Silicone Oil
(U)
Vegetable
Oil (V)
Density
25 oC
960
Kg/m3
980
Kg/m3
1020
Kg/m3
937
Kg/m3
Temp.
limits
-30~
200 oC
-10~
350 oC
-10~
400 oC
0~
250 oC
 
Temp.Working Pressure Range (kPa abs.)
20 oC>10>10>10>25
100 oC>25>25>25>50
150 oC>50>50>50>75
200 oC>75>75>75>100
250 oC >100>100>100
350 oC >100>100 
400 oC  >100 

EMC Performance Table
ItemsTest ItemsBasic StandardTest ConditionPerformance Level
1Radiated Interference (Housing)GB/T 9254-200830 MHz~1000 MHzOK
2Conducted Interference
(DC Power Port)
GB/T 9254-20080.15 MHz~30 MHzOK
3Electrostatic Discharge (ESD)
Immunity
GB/T 17626.2-20064kV (Line)
8kV (Air)
B
4RF Electromagnetic Field
Immunity
GB/T 17626.3-200610V/m (80 MHz~1 GHz)A
5Frequency Magnetic Field
Immunity
GB/T 17626.8-200630A/mA
6Electrical Fast Transient Burst
Immunity
GB/T 17626.4-20082kV/(5/50ns, 5kHz)B
7Surge ImmunityGB/T 17626.5-20081kV (Line to Line)
2kV (Line to Ground)
(1.2us/50us)
B
8Conducted Interference
Immunity induced by RF Field
GB/T 17626.6-20083V (150 KHz ~ 80 MHz)A

Dimensions
Intelligent Air (Differential) Pressure Transmitter with Remote Diaphragm Seals (ATEX)


Intelligent Air (Differential) Pressure Transmitter with Remote Diaphragm Seals (ATEX)
 
For more information, please contact Tosilon
Your Global Partner for Automation
www.tosilon.com
 
Intelligent Air (Differential) Pressure Transmitter with Remote Diaphragm Seals (ATEX)
Send your message to this supplier
Avatar
Mr. Mason. Ding
General Manager
*From:
To: Mr. Mason. Ding
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now